In highly urbanized area, lack of space limits the application of most stormwater quality
treatment technologies. Oil/Grit Separators (OGSs) are preferred in these cases due to their
compact size and reasonable solids removal efficiency. The objective of this research is to
identify the challenges and practical potential solutions of solids treatment performance
testing on a full-scaled experimental vortex device (EVD) adopting TRCA’s regulatory
guideline titled the “Procedure for Laboratory Testing of Oil/Grit Separators” (referred to
in this paper as the Procedure) which stipulates the standards of sediments and oil removal
tests in Canada. The test results indicated that: (1) TSS treatment efficiency of EVD was
observed to decline with the particle size and flow rate; and (2) the average overall TSS
treatment efficiency decreased from 52% to 44% as the flow rate doubled.