Parametric analysis of energy recovery ventilation performance in the high rise residential sector: a Toronto case study

Download (2.05 MB)
thesis
posted on 2021-05-24, 10:01 authored by Adam Barker
The performance of energy recovery ventilation (ERV) units is analyzed for high rise residential buildings in the Toronto climate. ERV units are scrutinized by their ability to recover heating and cooling energy throughout the year. The rated effectiveness of ERV units is well documented through applicable Standards. Several factors are identified which have the potential to influence the impact of ERVs under actual operation conditions, including infiltration rate, ERV leakage flows, temperature set points, and operation schemes. EnergyPlus is used to represent a typical residential suite, through which the impacts of the parameters are studied. Performance of the ERV model is validated through comparison to collected temperature and humidity data from an operating ERV unit in the GTA. Results indicate that leakage flows within the ERV represent the highest potential contributor to ERV performance. Economizer control strategies are determined as a viable option for improving performance during warmer seasons. The performance of energy recovery ventilation (ERV) units is analyzed for high rise residential buildings in the Toronto climate. ERV units are scrutinized by their ability to recover heating and cooling energy throughout the year. The rated effectiveness of ERV units is well documented through applicable Standards. Several factors are identified which have the potential to influence the impact of ERVs under actual operation conditions, including infiltration rate, ERV leakage flows, temperature set points, and operation schemes. EnergyPlus is used to represent a typical residential suite, through which the impacts of the parameters are studied. Performance of the ERV model is validated through comparison to collected temperature and humidity data from an operating ERV unit in the GTA. Results indicate that leakage flows within the ERV represent the highest potential contributor to ERV performance. Economizer control strategies are determined as a viable option for improving performance during warmer seasons.

History

Language

English

Degree

  • Master of Building Science

Program

  • Building Science

Granting Institution

Ryerson University

LAC Thesis Type

  • MRP

Year

2014

Usage metrics

    Building Science (Theses)

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC