posted on 2023-08-24, 21:39 authored by Vaskar Gnyawali, Mohammadali Saremi, Michael KoliosMichael Kolios, Scott TsaiScott Tsai
We present a simple technique to generate stable hydrodynamically focused flows by driving the flow with hydrostatic pressure from liquid columns connected to the inlets of a microfluidic device. Importantly, we compare the focused flows generated by hydrostatic pressure and classical syringe pump driven flows, and find that the stability of the hydrostatic pressure driven technique is significantly better than the stability achieved via syringe pumps, providing fluctuation-free focused flows that are suitable for sensitive microfluidic flow cytometry applications. We show that the degree of flow focusing with the hydrostatic method can be accurately controlled by the simple tuning of the liquid column heights. We anticipate that this approach to stable flow focusing will find many applications in microfluidic cytometry technologies. Keywords: Microfluidics, hydrodynamic flow focusing, hydrostatic pressure driven flows, flow cytometry